Determine exact position of your fireplace, including hearth height, width, and depth, (if applicable). If possible, place fireplace in such a
manner that vent termination will be placed between two studs, eliminating the need for additional framing.
If masonry is to be used (optional), prepare the necessary foundation for the masonry load. When masonry construction is used, a lintel
must be used over top of fireplace to support the added weight.
Build hearth to desired size and height. If a hearth extension is desired, combustible material may be used.
Follow vent pipe manufacturer‟s installation instructions for horizontal
terminations. Include required vent manufacturer‟s wall pass-thru clearances
when determining framing dimensions.
CAUTION: Cold air transfer area. The surrounding fireplace chase must comply with all clearances as outlined in this manual and be
constructed in compliance with local building codes. Outside walls should be insulated to prevent cold air from entering room.
CAUTION: Due to high temperatures, this fireplace should be located out of traffic areas and away from furniture and draperies.
HORIZONTAL TERMINATIONS
Follow vent pipe manufacturer‟s installation instructions for vertical
terminations. A minimum 1” (25mm) clearance on all sides of vertical
vent pipe must be maintained.
VERTICAL TERMINATIONS
FRAMING
WARNING: Install fireplace on hard metal or wood surface extending the full width and depth of fireplace.
Minimum platform size: 40-7/8” (1038mm) wide x 19” (483mm) deep.
FIRE HAZARD: Do NOT install directly on carpeting, vinyl, or any combustible material other than wood.
IMPORTANT: Vent cap location must be in compliance with guidelines on page #18 of this manual.
NOTE: Consider height of hearth finish material (stone, brick, etc.) when building fireplace platform. Bottom of fireplace must be level
with finished hearth to allow for lower grill operation and proper fit of optional decorative full door faces.
PAGE 9
MINIMUM HORIZONTAL FRAMING DIMENSIONS
VENT PIPE CENTER (A) FRAMED OPENING TOP (B)
RIGID PIPE 33-3/8” (848mm) Per vent manufacturer requirements
FLEX PIPE 36-7/8” (937mm) Per vent manufacturer requirements
NOTE: The included Horizontal Vent Heat Shield is not used for
vertical configurations.